view auto/endianness @ 7162:8b84d60ef13d

Fixed "changing binary" when reaper is not init. On some systems, it's possible that reaper of orphaned processes is set to something other than "init" process. On such systems, the changing binary procedure did not work. The fix is to check if PPID has changed, instead of assuming it's always 1 for orphaned processes.
author Ruslan Ermilov <ru@nginx.com>
date Tue, 28 Nov 2017 12:00:24 +0300
parents e3faa5fb7772
children
line wrap: on
line source


# Copyright (C) Igor Sysoev
# Copyright (C) Nginx, Inc.


echo $ngx_n "checking for system byte ordering ...$ngx_c"

cat << END >> $NGX_AUTOCONF_ERR

----------------------------------------
checking for system byte ordering

END


cat << END > $NGX_AUTOTEST.c

int main(void) {
    int i = 0x11223344;
    char *p;

    p = (char *) &i;
    if (*p == 0x44) return 0;
    return 1;
}

END

ngx_test="$CC $CC_TEST_FLAGS $CC_AUX_FLAGS \
          -o $NGX_AUTOTEST $NGX_AUTOTEST.c $NGX_LD_OPT $ngx_feature_libs"

eval "$ngx_test >> $NGX_AUTOCONF_ERR 2>&1"

if [ -x $NGX_AUTOTEST ]; then
    if $NGX_AUTOTEST >/dev/null 2>&1; then
        echo " little endian"
        have=NGX_HAVE_LITTLE_ENDIAN . auto/have
    else
        echo " big endian"
    fi

    rm -rf $NGX_AUTOTEST*

else
    rm -rf $NGX_AUTOTEST*

    echo
    echo "$0: error: cannot detect system byte ordering"
    exit 1
fi