view auto/have_headers @ 6927:c36d160cd4e0

Access log: removed dead ev->timedout check in flush timer handler. The ev->timedout flag is set on first timer expiration, and never reset after it. Due to this the code to stop the timer when the timer was canceled never worked (except in a very specific time frame immediately after start), and the timer was always armed again. This essentially resulted in a buffer flush at the end of an event loop iteration. This behaviour actually seems to be better than just stopping the flush timer for the whole shutdown, so it is preserved as is instead of fixing the code to actually remove the timer. It will be further improved by upcoming changes to preserve cancelable timers if there are other timers blocking shutdown.
author Maxim Dounin <mdounin@mdounin.ru>
date Tue, 07 Mar 2017 18:51:12 +0300
parents d620f497c50f
children
line wrap: on
line source


# Copyright (C) Igor Sysoev
# Copyright (C) Nginx, Inc.


cat << END >> $NGX_AUTO_HEADERS_H

#ifndef $have
#define $have  1
#endif

END