view src/core/ngx_proxy_protocol.h @ 7570:d6cf51af8a3d

HTTP/2: fixed possible alert about left open socket on shutdown. This could happen when graceful shutdown configured by worker_shutdown_timeout times out and is then followed by another timeout such as proxy_read_timeout. In this case, the HEADERS frame is added to the output queue, but attempt to send it fails (due to c->error forcibly set during graceful shutdown timeout). This triggers request finalization which attempts to close the stream. But the stream cannot be closed because there is a frame in the output queue, and the connection cannot be finalized. This leaves the connection open without any timer events leading to alert. The fix is to post write event when sending output queue fails on c->error. That will finalize the connection.
author Ruslan Ermilov <ru@nginx.com>
date Mon, 23 Sep 2019 15:45:32 +0300
parents a420cb1c170b
children 06b01840bd42
line wrap: on
line source


/*
 * Copyright (C) Roman Arutyunyan
 * Copyright (C) Nginx, Inc.
 */


#ifndef _NGX_PROXY_PROTOCOL_H_INCLUDED_
#define _NGX_PROXY_PROTOCOL_H_INCLUDED_


#include <ngx_config.h>
#include <ngx_core.h>


#define NGX_PROXY_PROTOCOL_MAX_HEADER  107


u_char *ngx_proxy_protocol_read(ngx_connection_t *c, u_char *buf,
    u_char *last);
u_char *ngx_proxy_protocol_write(ngx_connection_t *c, u_char *buf,
    u_char *last);